Engine 142's New Air Primer: 100-feet of Suction Hose - 1:53 minutes - 1012 gpm!!!
Email Print RSS Facebook Twitter RSS

By Fire Lieutenant Mark Davis
August 1, 2012

Winfield VFD's Engine 142 (2007 4-Guys 1500gpm pumper) is the first pumper in the U.S.A to have the Trident Automatic Air Primer installed on it. On July 31st, the Tuesday Night Duty Crew decided to see what the primer could do with an extened suction layout. So the folks used all of the 6-inch suction hose owned by the department, connected it all together and then connected to a dry hydrant, and gave the automatic air primer a real workout.

The first test resulted in a time of 2:40 minutes from primer activation to discharge pressure at the pump. A flow of 791 gpm was obtained using the pumper's high-flow discharge and a Hose Monster flow device.

There was a significant air leak at the dry hydrant suction head that could not be fixed, so a second test was set-up using a floating strainer. The second test resulted in an even faster time of 1:53 minutes from primer activation until discharge pressure pressure at the pump. A flow of 1012 gpm was obtained using the pumper's high-flow discharge.

The lift for both tests was under 10-ft.

The automatic air primer has no moving parts and has the ability to automatically engage when a loss of prime begins to occur. The "100-ft" suction hose test also shows the ability of the air primer to run for long periods of time without concern over damage or overheating. Trying to evacuate 100-ft of air using a traditional, rotary vane primer pump would be a challange in terms of overheating the vanes and the increased electrical draw on the vehicle's electrical system.

The WVFD thanks the folks at Trident Emergency Products for selecting Winfield to receive the first installation and the folks at 4-Guys for handling the installation.


Add a Comment Add a Comment 0 Comment(s)


Website Designed and Hosted By: Content Proudly Maintained By: Contact Info:
Firehouse Solutions
www.FirehouseSolutions.com
Winfield Community Volunteer Fire Department
1320 West Old Liberty Road
Sykesville, MD 21784
Emergency Dial 911
Non-Emergency: 410-795-1333
Station Fax: 410-795-1375
E-mail: info@winfieldvfd.org
Copyright © 2024 Firehouse Solutions (A Service of Technology Reflections, Inc.)